4.5.9. Removal and installation of the regulator of phases of gas distribution
Regulator of phases of gas distribution
|
1, 3, 15 — Bolts 2, 7, 12 — Covers 4 — Fittings 6 — the Nut 13 — the Right asterisk 14 — the Adjusting piston 14a — the Conic spring |
16 — the Flange 17 — Pruzhina 19 — the Lock ring 20 — the Plug 21 — the Finger 22 — the Camshaft |
Removal of an asterisk of the left camshaft
|
6 — the Nut 12 — the Cover 13 — the Asterisk 14 — the Adjusting piston 14a — the Conic twisted spring |
|
Removal
|
1. Remove forward covers of both regulators. |
2. Install the piston of the first cylinder in situation 45 ° before VMT. |
|
3. Block camshafts by means of cores (1). |
|
4. Mark a GRM drive chain arrangement concerning asterisks of camshafts. |
|
5. Remove a natyazhitel of a chain of the GRM drive. 6. Remove the top directing levers. Remove only the right lever for the right regulator. 7. Remove an asterisk of the right final camshaft. |
8. Turn off a bolt (3) fastenings of fittings (4). |
|
9. Turn off a nut (6), uncover (12), an asterisk of the left camshaft (13) with the adjusting piston (14) and a conic spring (14a). Turn off bolts (15) and remove a flange from the inlet camshaft. |
|
|
Installation
|
1. Tighten a flange (16) on the inlet camshaft (22). Be convinced of correctness of installation of the directing fingers (21). Replace bolts (15). |
2. Insert a spherical spring (14a) and install the adjusting piston (14) on a flange (16) in the fixed situation (blocking tooth In). 3. Establish an asterisk of the inlet camshaft in the fixed situation (blocking tooth In) on vents of the adjusting piston (14); lift a GRM drive chain for providence of this procedure up. |
|
4. Turn off a persistent nut. Hold the regulator assembled for carrying out this operation. 5. Establish a cover (12). 6. Wrap a nut (6). Hold the camshaft (22) by means of a key (03). 7. Install fittings (4) in the fixed situation. |
|
|