12.3.11. The regulator of clearance of a forward suspension bracket - an installation detail
Location of the regulator of clearance of a forward suspension bracket
|
6 — the Regulator of clearance of a forward suspension bracket 52 — the Distributor 54 — the Connecting lever Р — the Steel pipeline |
|
Removal
|
1. Disconnect the forcing pipeline (P). Merge oil in a suitable container.
|
|
2. Turn off bolts (shooter) and uncover (a) on the right wheel arch. |
|
3. Remove an arm (shooter) on a side beam, - on models with M119 and M120 engines at first it is necessary to remove a heat-shielding guard. |
|
4. Remove clamps (A) from the valve of adjustment of clearance of a forward suspension bracket (Y37) and remove it, (except the models delivered to the USA). |
|
5. Disconnect the forcing pipeline (PV and TV) from the regulator and the distributor (52) and remove both pipelines. 6. Unscrew the connecting lever (15) from the regulator. |
|
7. By means of a key disconnect the forcing (S1) and (S2) pipelines from the regulator. |
|
8. Turn off bolts (52b) of fastening of the regulator (Y36) and remove it. |
|
|
Installation
Installation is carried out as it should be, the return to removal.