10.3.3. Removal and CV JOINT installation of power shafts and their protective covers
Removal 
Design of hinges of a power shaft and detail of installation of their protective covers 
|  | 
| 37a — the Power shaft 37b — the External hinge
 37s — the Internal hinge
 37d — a hinge Nave
 37e — the Ball
 37f — the Separator
 | 37g — the Lock ring 37h — the Cover
 37i — the Epiploon
 37k — the Collar
 37l, 37m — Protective covers
 | 
|  | 
| 
| 1. Remove a power shaft. 2. Remove collars (37k).
 3. Uncover (37h) and an epiploon (37i) on a hinged ring (37s).
 4. Remove a lock ring (37g).
 5. Remove a protective cover (37l) with an epiploon (37i).
 6. Remove the internal hinge (37s) - (37f) from a power shaft.
 7. Remove a protective cover (37m).
 |  | 
Installation 
Installation is carried out as it should be, the return to removal. Stuffing of the internal hinge will require 
about 120-150 g of lubricant, external -
 120 g.