10.3.3. Removal and CV JOINT installation of power shafts and their protective covers
Removal
Design of hinges of a power shaft and detail of installation of their protective covers
|
37a — the Power shaft 37b — the External hinge 37s — the Internal hinge 37d — a hinge Nave 37e — the Ball 37f — the Separator |
37g — the Lock ring 37h — the Cover 37i — the Epiploon 37k — the Collar 37l, 37m — Protective covers |
|
1. Remove a power shaft. 2. Remove collars (37k). 3. Uncover (37h) and an epiploon (37i) on a hinged ring (37s). 4. Remove a lock ring (37g). 5. Remove a protective cover (37l) with an epiploon (37i). 6. Remove the internal hinge (37s) - (37f) from a power shaft. 7. Remove a protective cover (37m). |
|
Installation
Installation is carried out as it should be, the return to removal. Stuffing of the internal hinge will require
about 120-150 g of lubricant, external -
120 g.